GENESIS KOMPRESSOREN REFRIGERATED AIR DRYER
Working Principle: The dryer is divided into three system: heat exchange, refrigeration and electric
control system. Compressed air enters the air-air or air-water pre-cooler for removing heat content, then it
enters the air or air heat exchanger and being cooled down to a lower temperature. After it enters the
evaporator, the air to refrigerant heat reduce the air temperature down to 2-50°C (dew point temp.), the
moisture will be condensed into liquid, which will be separated by separator and be drained off by the
solenoid drain valve. In the mean time, low temperature air pass throught the air to air heat exchanger,
then goes to application after reaching designed temperature.
GENESIS KOMPRESSOREN PIPELINE AIR FILTER
Function: The pipeline filter can filter out impurities such as dirt, oil, water, etc. Through the three.
stage precision filtration of compressed air filter A, B, C, from coarse to fine, it can effectively remove
99.9% of impurities.